CHP GT (Combined Heat and Power Gas Turbine)
The combined heat-and-power gas turbine represents a gas turbine that is directly used to co-produce heat and power from gas. It is connected to the district heating network.
Attribute |
Description |
Standard value |
Unit |
Data type |
|---|---|---|---|---|
|
If set to ‘true’, the technology will be considered in the energy system model (this does not necessarily mean it will be used). Only relevant for optimisation. |
False |
— |
bool |
|
If set to ‘true’, existing gas turbine will be deployable. |
False |
— |
bool |
|
Maximum capacity (electric power output) of newly built CHP gas turbines. |
inf |
kW |
float |
|
Force implementation of maximum capacity specified in kW_el_max. Only relevant for optimisation. |
False |
kW |
bool |
|
Heating value (lower) of gas |
46 |
MJ/kg |
float |
|
Electrical conversion effiency. |
0.35 |
float |
|
|
Heat-to-power (htp) ratio (kW_th/kW_el) |
1.5 |
kW_th/kW_el |
float |
|
Price of gas. |
0.13 |
CHF/kWh |
float |
|
Carbon-dioxide intensity of technology output (annual average value). |
0.645 |
kg CO2/kWh |
float |
|
Expected lifetime of technology before replacement is required. |
25 |
years |
int |
|
CAPEX cost of technology per unit of capacity. |
5000 |
CHF/kWp |
float |
|
OPEX cost of technology per unit of capacity. |
10 |
CHF/kWp/year |
float |
|
Interest rate for computing levelised costs (if required). |
0.025 |
— |
float |
|
Is it allowed to export heat? |
True |
— |
bool |
|
Export subsidy for heat. Can be needed when optimizing in the LP-mode. |
1e-05 |
CHF/kWh |
float |
The relationship between the in- and outflows is given by
The symbols and names of the flows are
|
Waste Heat |
|
Inflow Gas |
|
Outflow Electricity |
|
Outflow Heat |