Gas Turbine Central Plant

Attribute

Unit

Data type

Description

deployment

bool

If set to ‘true’, the technology will be considered in the energy system model (this does not necessarily mean it will be used). Only relevant for optimisation.

kW_el_max

kW

float

Maximum electrical power output.

force_cap_max

kW

bool

Force implementation of maximum capacity specified in kW_el_max. Only relevant for optimisation.

cap_min_use

kW

float

Minimum capacity to use.

hv_gas_MJpkg

MJ/kg

float

Heating value (lower) of gas

eta_el

float

Electrical conversion effiency.

htp_ratio

kW_th/kW_el

float

Heat-to-power (htp) ratio (kW_th/kW_el)

co2_intensity

kg CO2/kWh

float

Carbon-dioxide intensity of technology output (annual average value).

lifetime

years

int

Expected lifetime of technology before replacement is required.

capital_cost

CHF/kWp

float

CAPEX cost of technology per unit of capacity.

maintenance_cost

CHF/kWp/year

float

OPEX cost of technolgoy per unit of capacity

interest_rate

float

Interest rate for computing levelised costs (if required).