Solar Thermal
This technology represents locally mounted solar thermal collectors on buildings. They can supply heat to the individual buildings.
Attribute |
Description |
Standard value |
Unit |
Data type |
|---|---|---|---|---|
|
If set to ‘true’, the technology will be considered in the energy system model (this does not necessarily mean it will be used). Only relevant for optimisation. |
True |
— |
bool |
|
Maximum thermal capacity (i.e. heat output). |
inf |
kW |
float |
|
Overall conversion efficiency from solar radiation to heat output. |
0.7 |
— |
float |
|
Carbon-dioxide intensity of technology output (annual average value). |
0 |
kg CO2/kWh |
float |
|
Expected lifetime of technology before replacement is required. |
25 |
years |
int |
|
Interest rate for computing levelised costs (if required). |
0.025 |
— |
float |
|
CAPEX cost of technology per unit of capacity. |
2857 |
CHF/kWp |
float |
|
CAPEX cost of technology per unit of capacity (when device has reached the end of life) |
1000 |
CHF/kWp |
float |
|
OPEX cost of technology. |
10 |
CHF/kWp/year |
float |
The symbols and names of the flows are
|
Outflow Heat |