Model Output
Hourly Results
Column |
Type |
Unit |
Description |
|---|---|---|---|
d_e |
float |
kWh |
Total electricity demand (incl. Heating and household demand) |
d_e_ev |
float |
kWh |
Electricity demand for electric vehicles (subset of d_e) |
d_e_h |
float |
kWh |
Electricity demand due to heating (e.g. heat pump, electric heater) (subset of d_e) |
d_e_hh |
float |
kWh |
Electricity demand other than heating (i.e. “household”) (subset of d_e) |
d_h |
float |
kWh |
Total heating demand |
d_h_hw |
float |
kWh |
Heat demand for hot water (subset of d_h) |
d_h_s |
float |
kWh |
Heat demand for space heating (subset of d_h) |
l_q_e_bes |
float |
kWh |
Battery energy storage: storage losses |
l_q_h_tes |
float |
kWh |
Thermal energy storage: storage losses |
l_q_h_tesdc |
float |
kWh |
Thermal energy storage (decentralised): storage losses |
l_u_e_bes |
float |
kWh |
Battery energy storage: charging losses |
l_u_h_tes |
float |
kWh |
Thermal energy storage: charging losses |
l_u_h_tesdc |
float |
kWh |
Thermal energy storage (decentralised): charging losses |
l_v_e_bes |
float |
kWh |
Battery energy storage: discharging losses |
l_v_h_tes |
float |
kWh |
Thermal energy storage: discharging losses |
l_v_h_tesdc |
float |
kWh |
Thermal energy storage (decentralised): discharging losses |
m_e |
float |
kWh |
Total electricity import to community |
m_e_cbimport |
float |
kWh |
Electricity import from cross-border, i.e. from other countries (subset of m_e) |
m_e_ch |
float |
kWh |
Electricity import from within Switzerland (subset of m_e) |
m_e_ch_conventional_chp |
float |
kWh |
Electricity import form within Switzerland coming from conventional chp plants (subset of m_e_ch) |
m_e_ch_hydro |
float |
kWh |
Electricity import form within Switzerland coming from hydro power (subset of m_e_ch) |
m_e_ch_nuclear |
float |
kWh |
Electricity import form within Switzerland coming from nuclear power (subset of m_e_ch) |
m_e_ch_renewable_chp |
float |
kWh |
Electricity import form within Switzerland coming from renewable chp plants (subset of m_e_ch) |
m_e_ch_renewable_other |
float |
kWh |
Electricity import form within Switzerland coming from other renewable sources (subset of m_e_ch) |
m_h |
float |
kWh |
Heat import (via district heating) |
m_gas |
float |
kWh |
Gas import |
m_oil |
float |
kWh |
Oil import |
m_wd |
float |
kWh |
Wood import |
q_e_bes |
float |
kWh |
Battery energy storage stored electricity |
q_h_tes |
float |
kWh |
Thermal energy storage stored heat |
q_h_tesdc |
float |
kWh |
Thermal energy storage (decentralised) stored heat |
s_wd |
float |
kWh |
total wood supply |
s_wd_rem |
float |
kWh |
wood supply remaining |
s_wet_bm |
float |
kWh |
total wet biomass supply |
s_wet_bm_rem |
float |
kWh |
wet biomass supply remaining |
sos_bes |
float |
– |
Battery energy storage: state of storage |
sos_tes |
float |
– |
Thermal Energy storage: state of storage |
sos_tesdc |
float |
– |
Thermal Energy storage (decentralised): state of storage |
u_e_aguh |
float |
kWh |
electricity demand anaerobic digestion upgrade hydrogen |
u_e_bes |
float |
kWh |
Battery energy storage added electricity |
u_e_eh |
float |
kWh |
Electric heater electricity input |
u_e_hp |
float |
kWh |
Heat pump electricity input |
u_e_hpcp |
float |
kWh |
Heat pump (centralised plant) electricity input |
u_e_hydp |
float |
kWh |
electricity demand hydrogen production |
u_e_wgu |
float |
kWh |
electricity demand wood gasification upgrade |
u_e_wguh |
float |
kWh |
electricity demand wood gasification upgrade hydrogen |
u_gas_chpgt |
float |
kWh |
Gas turbine combined heat and power: gas input |
u_gas_chpgt_kg |
float |
kg |
Gas turbine combined heat and power: gas input |
u_gas_gb |
float |
kWh |
Gas boiler gas input |
u_gas_gb_kg |
float |
kg |
Gas boiler gas input |
u_h_hp |
float |
kWh |
heat pump heat input |
u_h_hpcp |
float |
kWh |
heat pump (centralised plant) heat input |
u_h_tes |
float |
kWh |
Thermal energy storage added heat |
u_h_tesdc |
float |
kWh |
Thermal energy storage (decentralised) added heat |
u_hyd_aguh |
float |
kWh |
hydrogen demand anaerobic digestion upgrade hydrogen |
u_hyd_wguh |
float |
kWh |
hydrogen demand wood gasification upgrade hydrogen |
u_oil_ob |
float |
kWh |
Oil boiler oil input |
u_oil_ob_kg |
float |
kg |
Oil boiler oil input |
u_wd_wgu |
float |
kWh |
wood demand wood gasification upgrade |
u_wd_wguc |
float |
kWh |
wood demand wood gasification CHP |
u_wd_wguh |
float |
kWh |
wood demand wood gasification upgrade hydrogen |
u_wet_bm_agu |
float |
kWh |
wet biomass demand anaerobic digestion upgrade |
u_wet_bm_aguc |
float |
kWh |
wet biomass demand anaerobic digestion CHP |
u_wet_bm_aguh |
float |
kWh |
wet biomass demand anaerobic digestion upgrade hydrogen |
u_wet_bm_hg |
float |
kWh |
wet biomass demand hydrothermal gasification |
u_wood_wb |
float |
kWh |
Wood boiler wood input |
u_wood_wb_kg |
float |
kg |
Wood boiler wood input |
v_co2_bm |
float |
kg |
Biomass: CO2 emissions |
v_co2_chpgt |
float |
kg |
Gas turbine combined heat and power: CO2 emissions |
v_e_aguc |
float |
kWh |
electricity output anaerobic digestion CHP |
v_e_aguc_exp |
float |
kWh |
electricity output anaerobic digestion CHP export |
v_e_bes |
float |
kWh |
Battery energy storage extracted electricity |
v_e_bm |
float |
kWh |
Biomass electricity output |
v_e_bm_cons |
float |
kWh |
Biomass electricity output consumed locally |
v_e_bm_exp |
float |
kWh |
Biomass electricity output exported to the grid (i.e. excess) |
v_e_chpgt |
float |
kWh |
Gas turbine combined heat and power: electricity output |
v_e_hydro |
float |
kWh |
Local hydro power electricity output |
v_e_hydro_cons |
float |
kWh |
Local hydro power electricity output consumed locally |
v_e_hydro_exp |
float |
kWh |
Local hydro power electricity output exported to the grid (i.e. excess) |
v_e_hydro_pot |
float |
kWh |
Total local hydro power potential (installed + additional potential) |
v_e_hydro_pot_remain |
float |
kWh |
Remaining additional local hydro power potential (excl. installed capacity) |
v_e_pv |
float |
kWh |
Solar PV electricity output |
v_e_pv_cons |
float |
kWh |
Solar PV electricity output consumed locally |
v_e_pv_exp |
float |
kWh |
Solar PV electricity output exported to the grid (i.e. excess) |
v_e_pv_pot |
float |
kWh |
Total solar PV potential (installed + additional potential) |
v_e_pv_pot_remain |
float |
kWh |
Remaining additional solar PV potential (excl. installed capacity) |
v_e_wguc |
float |
kWh |
electricity output wood gasification CHP |
v_e_wguc_exp |
float |
kWh |
electricity output wood gasification CHP export |
v_e_wp |
float |
kWh |
Wind power electricity output for generation counting towards local production |
v_e_wp_ch |
float |
kwh |
Wind power electricity output for generation counting towards national production |
v_e_wp_cons |
float |
kWh |
Wind power electricity output consumed locally |
v_e_wp_exp |
float |
kWh |
Wind power electricity output exported to the grid (i.e. excess) |
v_e_wp_pot |
float |
kWh |
Total wind power potential (installed + additional potential); will be either profile type ‘annual’ or ‘winter’. |
v_e_wp_pot_annual |
float |
kWh |
Total wind power potential (installed + additional potential) using ‘annual’ profile (balanced across the year) |
v_e_wp_pot_annual_kWhpkW |
float |
kWh/kW |
Wind power potential (installed + additional potential) per capacity using ‘annual’ profile (balanced across the year) |
v_e_wp_pot_remain |
float |
kWh |
Remaining additional wind power potential (excl. installed capacity) |
v_e_wp_pot_winter |
float |
kWh |
Total wind power potential (installed + additional potential) using ‘winter’ profile (geared towards winter production) |
v_e_wp_pot_winter_kWhpkW |
float |
kWh/kW |
Wind power potential (installed + additional potential) per capacity using ‘winter’ profile (geared towards winter production) |
v_gas_agu |
float |
kWh |
gas output anaerobic digestion upgrade |
v_gas_aguh |
float |
kWh |
gas output anaerobic digestion upgrade hydrogen |
v_gas_hg |
float |
kWh |
gas output anaerobic hydrothermal gasification |
v_gas_wgu |
float |
kWh |
gas output wood gasification upgrade |
v_gas_wguh |
float |
kWh |
gas output wood gasification upgrade hydrogen |
v_h_aguc |
float |
kWh |
heat output anaerobic digestion CHP |
v_h_aguh |
float |
kWh |
heat output anaerobic digestion upgrade hydrogen |
v_h_bm |
float |
kWh |
Biomass heat ouput |
v_h_chpgt |
float |
kWh |
Gas turbine combined heat and power: heat output |
v_h_dh |
float |
kWh |
District heating heat output |
v_h_eh |
float |
kWh |
Electric heater heat output |
v_h_gb |
float |
kWh |
Gas boiler heat output |
v_h_hp |
float |
kWh |
Heat pump heat output |
v_h_hpcp |
float |
kWh |
Heat pump (centralised plant) heat output |
v_h_ob |
float |
kWh |
Oil boiler heat output |
v_h_other |
float |
kWh |
Heat output from other sources (unknown) |
v_h_solar |
float |
kWh |
Solar thermal heat output |
v_h_tes |
float |
kWh |
Thermal energy storage extracted heat |
v_h_tesdc |
float |
kWh |
Thermal energy storage (decentralised) extracted heat |
v_h_wb |
float |
kWh |
Wood boiler heat output |
v_h_wgu |
float |
kWh |
heat output wood gasification upgrade |
v_h_wguc |
float |
kWh |
heat output wood gasification CHP |
v_h_wguh |
float |
kWh |
heat output wood gasification upgrade hydrogen |
v_hyd_hydp |
float |
kWh |
hydrogen output hydrogen production |
u_gas_gtcp |
float |
kWh |
Gas turbine central plant input |
u_gas_gtcp_kg |
float |
kg |
Gas turbine central plant input |
v_e_gtcp |
float |
kWh |
Gas turbine central plant output: electricity |
v_steam_gtcp |
float |
kWh |
Gas turbine central plant output: steam |
v_co2_gtcp |
float |
kg |
Gas turbine central plant: CO2 emissions |
u_steam_st |
float |
kWh |
Steam turbine input |
v_e_st |
float |
kWh |
Steam turbine output: electricity |
v_e_st_gtcp |
float |
kWh |
Steam turbine output: electricity stemming from centralised gas turbine (subset of v_e_st) |
v_e_st_wbcp |
float |
kWh |
Steam turbine output: electricity stemming from centralised wood boiler (subset of v_e_st) |
v_h_st |
float |
kWh |
Steam turbine output: heat |
v_h_st_gtcp |
float |
kWh |
Steam turbine output: heat stemming from centralised gas turbine (subset of v_h_st) |
v_h_st_wbcp |
float |
kWh |
Steam turbine output: heat stemming from centralised wood boiler (subset of v_h_st) |
v_co2_st |
float |
kg |
Steam turbine: CO2 emissions |
u_wd_wbcp |
float |
kWh |
Wood boiler central plant input |
u_wd_wbcp_kg |
float |
kg |
Wood boiler central plant input |
v_steam_wbcp |
float |
kWh |
Wood boiler central plant output: steam |
v_co2_wbcp |
float |
kg |
Wood boiler central plant: CO2 emissions |
u_msw_wte |
float |
kWh |
Waste-to-energy plant input: municipal solid waste |
u_msw_wte_kg |
float |
kg |
Waste-to-energy plant input: municipal solid waste |
v_e_wte |
float |
kWh |
Waste-to-energy plant output: electricity |
v_h_wte |
float |
kWh |
Waste-to-energy plant output: heat |
v_co2_wte |
float |
kg |
Waste-to-energy plant: CO2 emissions |
v_co2_tot |
float |
kg |
Total CO2 emissions (generation + import) |
Annual Results
in progress
Total Cost
in progress