CHP GT (Combined Heat and Power Gas Turbine)

The combined heat-and-power gas turbine represents a gas turbine that is directly used to co-produce heat and power from gas. It is connected to the district heating network.

Attribute

Description

Standard value

Unit

Data type

deployment

If set to ‘true’, the technology will be

considered in the energy system model

(this does not necessarily mean it will

be used). Only relevant for

optimisation.

False

bool

deploy_existing

If set to ‘true’, existing gas turbine

will be deployable.

False

bool

kW_el_max

Maximum capacity (electric power output)

of newly built CHP gas turbines.

inf

kW

float

force_cap_max

Force implementation of maximum capacity

specified in kW_el_max. Only relevant

for optimisation.

False

kW

bool

hv_gas_MJpkg

Heating value (lower) of gas

46

MJ/kg

float

eta_el

Electrical conversion effiency.

0.35

float

htp_ratio

Heat-to-power (htp) ratio (kW_th/kW_el)

1.5

kW_th/kW_el

float

gas_price_CHFpkWh

Price of gas.

0.13

CHF/kWh

float

co2_intensity

Carbon-dioxide intensity of technology

output (annual average value).

0.645

kg CO2/kWh

float

lifetime

Expected lifetime of technology before

replacement is required.

25

years

int

capital_cost

CAPEX cost of technology per unit of

capacity.

5000

CHF/kWp

float

maintenance_cost

OPEX cost of technology per unit of

capacity.

10

CHF/kWp/year

float

interest_rate

Interest rate for computing levelised

costs (if required).

0.025

float

allow_heat_export

Is it allowed to export heat?

True

bool

heat_export_subsidy

Export subsidy for heat. Can be needed

when optimizing in the LP-mode.

1e-05

CHF/kWh

float

The relationship between the in- and outflows is given by

\[\mathtt{v\_e\_chpgt} = \mathtt{eta\_el} \cdot \mathtt{u\_gas\_chpgt}\]
\[\mathtt{v\_h\_chpgt} = \mathtt{htp\_ratio} \cdot \mathtt{eta\_el} \cdot \mathtt{u\_gas\_chpgt}\]

The symbols and names of the flows are

v_h_chpgt_waste

Waste Heat

u_gas_chpgt

Inflow Gas

v_e_chpgt

Outflow Electricity

v_h_chpgt

Outflow Heat